Respected hospitals and healthcare organizations of all sizes turn to Armstrong as their trusted thermal utility partner. We’re global leaders in energy management, with experienced engineers in locations throughout the world, ready to satisfy the demands of your industry and solve the region-specific issues you face, day after day. Solving your problems and making things easier for you is the reason we’re here.

Products for the Healthcare Industry

 

 

Global Expertise for Healthcare Brochure

Cutting-edge solutions to meet current requirements.

Armstrong will help you implement and maintain a Legionella water safety management program that satisfies the latest requirements and industry standards. Our state-of-the-art hot water solutions are engineered for your most difficult healthcare challenges, which includes reducing risks for the growth and spreading of hospital-acquired infections.

Learn More

Smart Hot Water System Monitoring and Documentation Brochure

Armstrong Brings Net Zero Within Reach

For healthcare institutions with goals for increasing sustainability, reducing reliance on fossil fuels, and lowering environmental emissions, Armstrong is ready to help. We’ll design a tailor-made plan of action that leads you through your transition to net zero and beyond.

Learn More

See What Our Hardworking Products and Leading-Edge Technology Can Do for You

Select an area of the hospital to learn more about Armstrong’s state-of-the-art equipment, integrated systems and sustainable solutions for your mechanical and boiler rooms, sterile processing departments, washing and laundry facilities, and kitchens.

  • Washer
  • SPD
  • Mechanical Room
  • Laundry
  • Kitchen
  • Boiler Room
Click to close the tool.

Control Valve
Globe two-way single-seated body design valves satisfy the majority of control applications for HVAC, industrial and commercial markets. Learn More

Digital Recirculating Valve
Designed specifically to be the primary water temperature controller in a continuously pumped circulating hot water system. Digital technology provides enhanced water temperature control accuracy which resists zero system demand “temperature creep” without the use of a manual throttling valve or temperature activated pump shut-off device (aquastat). Learn More

Domestic Hot Water Heater (DHW)
Instantaneous, semi-instantaneous and tank-type storage water heaters. Our innovative hot water solutions place user safety and Legionella risk reduction at the forefront of hot water system design, operation and maintenance. Learn More

Float and Thermostatic Trap
Best choice for variable steam pressure users. Learn More

Humidifier
Direct steam injection is the most common form of steam humidifier. Before dispersing the steam, Armstrong’s direct-steam humidifiers condition steam by slowing it down, removing particulate matter, separating condensate from it, drying it and silencing it. Conditioned steam keeps components free of mineral deposits that can clog many forms of water-spray and evaporative-pan systems. Learn More

HW Heaters for Building Heating (HHW)
Advanced hot water system with digital control technology, visible on plant BAS or DDC.  Simple compact design.  Provides consistent temperature accuracy, enhanced operational efficiency and reduced maintenance. Learn More

Inverted Bucket Steam Trap
Best choice for drip trap applications and constant steam pressure users. Learn More

Pressure Reducing Valve
Externally piloted diaphragm-operated pressure reducing valve provides greater capacity than internally piloted valves and has greater accuracy (+/- 1% of pressure set point from 5–100% of flow) than piston operated valves. Learn More

Pumping Trap
Non-electric solution for moving condensate from low points, low pressures or vacuum spaces to an area of higher elevation or pressure. Learn More

Steam Trap Monitoring

AIM® is wireless monitoring technology that efficiently monitors and evaluates steam trap operation using non-intrusive technology combined with WirelessHART. Learn More

SAGE® keeps you fully informed, 24 hours a day by providing regular updates, precise documentation, custom-filtered reports, and real-time alerts to notify you immediately of any problems that arise. Learn More

Unit Heater
Components like motors, bearings, tubes, enclosures and fins are heavy-duty to ensure lasting performance. Learn More

Y-Type Strainer
No-leak, no-crush screen chambers, easy-in, easy-out screwed retainers. Learn More

Air Vent/ Vacuum Breaker
Prevents vacuum from forming in the equipment and releases air out of equipment during normal operation. Learn More

Back-Pressure Control Valve
Externally piloted throttling back-pressure valve that will function to maintain a constant upstream pressure. This valve is not a safety valve. Learn More

Flash Tank
Flash vessels designed to provide low velocity flash steam with no water carryover and quick payback for flash recovery investment.

Flow Meter
Unique, new flow meter combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter —with no straight run requirements. Learn More

Inverted Bucket Steam Trap
The best choice for drip trap applications and constant steam pressure users. Learn More

Pressure Reducing Valve
Externally piloted diaphragm-operated pressure reducing valve provides greater capacity than internally piloted valves and has greater accuracy (+/- 1% of pressure set point from 5–100% of flow) than piston operated valves. Learn More

Pumping Trap
Non-electric solution for moving condensate from low points, low pressures or vacuum spaces to an area of higher elevation or pressure. Learn More

Steam Separator
With correct sizing and proper drainage, these separators are designed to eliminate 98% of all entrained liquids and particles that are 10 microns and larger in size. Learn More

Air Vent/ Vacuum Breaker
Prevents vacuum from forming in the equipment and releases air out of equipment during normal operation. Learn More

Float and Thermostatic Trap
Best choice for variable pressure steam users. Learn More

Inverted Bucket Steam Trap
The best choice for drip trap applications and constant steam pressure users. Learn More

Mixing Valve
Generates hot water by mixing steam and cold water. Learn More

Pressure Regulator
Direct acting pressure reducing valve is self-contained (requires no external sensing line), compact and economical. Accuracy +/- 10%. Learn More

Pumping Trap
Non-electric solution for moving condensate from low points, low pressures or vacuum spaces to an area of higher elevation or pressure. Learn More

Temperature Control Valve
Maintains stable product temperatures by modulating the steam pressure supply to the equipment. Learn More

Air Heating Coils
Utilizing flash or low pressure steam to preheat combustion air increases boiler efficiency and saves fuel/energy. Preheating cold combustion air assures stable boiler operation. Learn More

Back-Pressure Control Valve
Externally piloted throttling back-pressure valve that will function to maintain a constant upstream pressure. This valve is not a safety valve. Learn More

Digital Control Valve
Emech® is digital hardware that is faster, simple, and smarter with one goal in mind: unparalleled performance in any application. Emech® digital control valves are available for steam/water and hot/cold water industrial service. Learn More

Digital Recirculating Valve
Designed specifically to be the primary water temperature controller in a continuously pumped circulating hot water system. Digital technology provides enhanced water temperature control accuracy which resists zero system demand “temperature creep” without the use of a manual throttling valve or temperature activated pump shut-off device (aquastat). Learn More

Domestic Hot Water Heater (DHW)
Instantaneous, semi-instantaneous and tank-type storage water heaters. Our innovative hot water solutions place user safety and Legionella risk reduction at the forefront of hot water system design, operation and maintenance. Learn More

Feed Water Control valve
Globe two-way single seated valves that deliver accurate and efficient control for most steam and liquid applications. The end user would be responsible for how it is controlled. Learn More

Flash Tank
Flash vessels designed to provide low velocity flash steam with no water carryover and quick payback for flash recovery investment.

Float and Thermostatic Trap
Best choice for variable pressure steam users. Learn More

Flow Meter
New and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter – with no straight run requirements. Learn More

HW Heaters for building heating (HHW)
Digital water temperature control technology with instantaneous heat exchanger design offers a level of hot water system temperature control accuracy previously considered unattainable. Digital-Flo® is compatible with Building Automation Systems on the BACnet™, LonWorks™, Modbus protocols and can be remotely programmed from and performance data is accessible by a Web browser. Learn More

Inverted Bucket Steam Trap
The best choice for drip trap applications and constant steam pressure users. Learn More

Pressure Reducing Valve
Externally piloted diaphragm-operated pressure reducing valve provides greater capacity than internally piloted valves and has greater accuracy (+/- 1% of pressure set point from 5–100% of flow) than piston operated valves. Learn More

Pumping Trap
Non-electric solution for moving condensate from low points, low pressures or vacuum spaces to an area of higher elevation or pressure. Learn More

Steam Trap Monitoring

AIM® is wireless monitoring technology that efficiently monitors and evaluates steam trap operation using non-intrusive technology combined with WirelessHART. Learn More

SAGE® keeps you fully informed, 24 hours a day by providing regular updates, precise documentation, custom-filtered reports, and real-time alerts to notify you immediately of any problems that arise. Learn More

Inverted Bucket Steam Trap
Best choice for drip trap applications and constant steam pressure users. Learn More

Pressure Reducing Valve
Externally piloted diaphragm-operated pressure reducing valve provides greater capacity than internally piloted valves and has greater accuracy (+/- 1% of pressure set point from 5–100% of flow) than piston operated valves. Learn More

Pumping Trap
Non-electric solution for moving condensate from low points, low pressures or vacuum spaces to an area of higher elevation or pressure. Learn More

Air Vent/Vacuum Breaker
A combination thermostatic air vent/vacuum breaker is ideally suited for steam-filled piping and vessels with modulating controls. The TAVB will vent air and other non-condensables and will break the vacuum that forms during steam modulation or system shut downs. Learn More

Inverted Bucket Steam Trap
The inverted bucket trap is the best choice for drip trap applications and constant steam pressure users. The Armstrong Trap Valve Station (TVS) combines the trap with two integral piston valves in a reliable and space-saving package. Learn More

Inverted Bucket Steam Trap with Universal Connector
The inverted bucket trap is best choice for drip trap applications and constant steam pressure users. The stainless steel version of the remarkable Armstrong Trap Valve Station (TVS) gives you two piston-style isolation valves, a test valve and an integral stainless steel strainer with blowdown valve—all merged in a single, versatile package. Learn More

Pressure Reducing Valve
Externally piloted diaphragm-operated pressure reducing valve provides greater capacity than internally piloted valves and has greater accuracy (+/- 1% of pressure set point from 5–100% of flow) than piston operated valves. Learn More

Pumping Trap
Non-electric solution for moving condensate from low points, low pressures or vacuum spaces to an area of higher elevation or pressure. Learn More

Steam Quality Meter
Automatic steam quality monitor that safely and reliably determines and communicates the dryness fraction of steam, allowing you to continuously, accurately, and efficiently monitor your steam system. Learn More

Steam Separator
With correct sizing and proper drainage, these separators are designed to eliminate 98% of all entrained liquids and particles that are 10 microns and larger in size. Learn More

Steam Trap Monitoring

AIM® is wireless monitoring technology that efficiently monitors and evaluates steam trap operation using non-intrusive technology combined with WirelessHART. Learn More

SAGE® keeps you fully informed, 24 hours a day by providing regular updates, precise documentation, custom-filtered reports, and real-time alerts to notify you immediately of any problems that arise. Learn More

+

Mechanical Room

+

Laundry

+

Kitchen

+

Boiler Room

+

Washer

+

SPD